Magnum's MPS1096 series

 


home > mps1096-000

MPS1096-000 300Watt Built-in UPS (BI-UPSā)
(PS/2 Case, ATX-Style Connector,Contact- Closure-Compatible Control Interface.)

MPS1096-000 300 Watt
MPS1096-000 is a plug-in replacement for conventional NLX/ATX form-factor switching power supplies. Units function as a normal power supply when AC line input is present and as truly on-line UPS during periods of power failure. Suitable for operation in conjunction with Magnum 24V battery packs.

Features:

300W Continuous DC Output Power . Active PFC . Full UPS functionality . Wideranging AC Input (47Hz to 63Hz, 85V to 264V) . Six DC Outputs . Standby Output (+5Vsb /2.0A) . Hold-up Time >17ms (No Battery Fitted) . Efficiency >65% (AC/DC & DC/DC) . Overtemperature, Overvoltage & Overcurrent Protection (Latched Shutdown) . Fan Speed Control . Standard UPS Contact Closure Compatible Interface . Logic On/Off . PS/2 (NLX) Style Case . ATX (NLX) 20-Way Motherboard Connector

1. Output (standard)

Nominal Voltage Min Load Max Load Regulation Ripple &
Noise
+5V DC 0.3A 20A (1) (3) +/-5% 50mV
+3.3V DC 0.5A 20A (1) (3) +/-5% 50mV
+12V1 DC 1A 8A (3) +/-5% (2) 120mV
+12V2 DC 1A 14A +/-5% 120mV
-12V DC 0A 0.5A +/-5% 120mV
+5Vsb 0A 2.0A +/-5% 50mV

(1) The combined loading on the +5V DC and the +3.3V DC outputs must not exceed 130W.
(2) Total regulation +7%, -5% during battery operation
(3) Operation at higher load currents permissible subject to appropriate constraints

2. Overcurrent

+5V, +3.3V, +12V Latched shutdown at <240VA (SELV Limit)
AC line or Logic On/Off recycle to restart.
-5V, -12V Short circuit protected. Latched shutdown.
AC line or Logic On/Off Recycle to restart.
+5Vsb Short Circuit protected. Automatic recovery

3. Overvoltage

+5V, +3.3V, +12V, -
12V, -5V
Latched shutdown at 5.6V to 7.0V, 3.76V to 4.8V, 13.0V to 15.6V respectively.
AC line or Logic On/Off Recycle to start.
+5Vsb Clamped at 5.9V to 6.5V. Automatic recovery

4. Backup Battery

Battery Type 24V Lead acid
Charger Voltage 27.6V (Temperature compensated)
Charger current limit 0.8A (Max)
Other NiMH Available on request

5. Approvals

Safety NEMKO(EN60950); TUV EN60950 or VDE EN60950; CSAC22.2 no950-95; IEC60950; UL60950
EMC EN55022: 1998+A1: 2000 Class B,
EN61000-3-2: 2000
EN61000-3-3: 1995+A1: 2001
CISPR 22: 1997+A1: 2000 Class B,
AS/NZS CISPR 22: 2002 Class B
Other CE Mark

6. Control Interface

PSON (LOGIC ON/OFF) BI-UPS® Input. TTL compatible siganl setting on/off state of unit.DC outputs enabled if pulled to logic low. DC outputs (excluding +5Vsb) disabled if driven to logic high or open circuited.
Power Good BI-UPS® Output. TTL compatible flag indicating status of +5V and +3.3V outputs. Set to logic high between 100ms and 500ms after both +5V and +3.3V outputs reach normal operating limits. Reset to logic low at least 1ms prior to either +5V or +3.3V outputs dropping out of normal operating limits.
Interface Enable BI-UPS® Input. Discrete signal to enable BI -UPS® control interface. Interface inactive if open circuited or held at logic low (-5 to -15V). Interface enabled if driven to logic high (+5 to +15V).
AC Fail BI-UPS® Output. RS232 compatible flag indicating failure of ac line voltage. ‘AC normal’ condition indicated by logic high (+5 to +15V); ‘AC fail’ by logic low (-5 to -15V)
Battery Backup Low BI-UPS® Output. RS232 compatible flag indicating battery backup voltage low. ‘Battery normal’ condition indicated by logic high (+5 to +15V); ‘Battery Low’ by logic low (-5 to -15V).
Shutdown BI-UPS® Input. Discrete signal enabled during battery back-up operation only. No action taken if held at logic low(<1V) or Open circuited. BI -UPS® shutdown initiated if driven to logic high (+5V to +15V).

7. Environmental

Storage Temperature -20 to +80°
Operating Temperature 0 to 50°C
Humidity 5 to 95% (non-condensing)
Maximum Altitude 12,000ft (operating), 40,000ft (non-operating)
Vibration Sine wave excited. 0.25G max acceleration, 10-250Hz
(operating)
MTBF >100,000 hours calculated per MIL-HBK-217 (full-load, 25°C,
ground benign, ex fan)

9. Cable Harness

Designator PIN COLOUR FUNCTION Cable Length
P1 JP2416V2-20S And JP2416V2-4S

1
2
3
4
5
6
7
8
9
10
11
12
13
13
14
15
16
17
18
19
20
21
22
23
24

Orange
Orange
Black
Red
Black
Red
Black
Grey
Purple
Yellow
Yellow
Orange
Orange
Brown
Blue
Black
Green
Black
Black
Black

Red
Red
Red
Black
+3.3VDC
+3.3VDC
COM
+5VDC
COM
+5VDC
COM
Power On
+5Vsb
+12V1DC
+12V1DC
+3.3VDC
+3.3VDC
+3.3VDC Sense
-12VDC
COM
PSON
COM
COM
COM

-5VDC
+5VDC
+5VDC
COM
500mm +20
/ -10
Pin8, 13sense,
14 + 16
24AWG
Pin9 20AWG
Remainder
18AWG
P2
Molex CL1270H00 15P
or Equiv.
1
2
3
4
5
Yellow
Black
Red
Black
Orange
+12V1DC
COM
+5VDC
COM
+3.3V
500mm +20
/ -10
20AWG
P3
Molex 39-01-2040
Or Equiv.
1
2
3
4
Black
Black
Yell/Black
Yell/Black

COM
COM
+12V2
+12V2

500mm +20
/ -10
16AWG
P4, P7
Amp 1-480424-0
Or Equiv.
1
2
3
4
Yellow
Black
Black
Red
+12V1
COM
COM
+5V
400mm +20
/ -10
18AWG
P5, P8
Amp 1-480424-0
Or Equiv.
1
2
3
4
Yellow
Black
Black
Red
+12V1
COM
COM
+5V
150mm +10
/ -10
18AWG
P6
Molex 171822-4
Or Equiv.
1
2
3
4
Red
Black
Black
Yellow
+5VDC
COM
COM
+12V1
150mm +10
/ -10
20AWG
P13
Alex 6420-02M1
1
2
Red
Black
Battery +VE
Battery –VE
200mm
14AWG
DB10A/DB10B
Molex 39-52-1105
1
2
3
4
5
6
7
8
9
10
Ribbon
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
Battery Low
N/C
Negative Bias
Shutdown
Signal Ground
N/C
Interface enable
AC Fail
N/C
N/C
440mm
28AWG

10. Mechanical - Standard Chassis

MPS1058-000

 

More information



 
 

 
home | about us | contact us | gaming power supplies | battery back up | custom design power supplies
markets | touch screen technology | display monitors screens | technical glossary | FAQs
magnum news | related links | site map

European Head Office
4 Michaelson Square, Kirkton Campus, Livingston, Scotland, EH54 7DP
Tel: + 44 (0) 1506 463 330 | Fax: + 44 (0) 01506 463 320 | E-mail: sales@magnumpower.com
 

© Copyright 2005 Magnum Power Solutions Ltd and its licensors - All Rights Reserved