home > mps1096-000
MPS1096-000 300Watt Built-in UPS (BI-UPSā)
(PS/2 Case, ATX-Style Connector,Contact-
Closure-Compatible Control Interface.)
MPS1096-000 is a plug-in replacement for conventional NLX/ATX
form-factor switching power supplies. Units function as a normal
power supply when AC line input is present and as truly on-line
UPS during periods of power failure. Suitable for operation in
conjunction with Magnum 24V battery packs.
Features:
300W Continuous DC Output Power . Active PFC . Full UPS functionality . Wideranging
AC Input (47Hz to 63Hz, 85V to 264V) . Six DC Outputs . Standby Output (+5Vsb /2.0A) .
Hold-up Time >17ms (No Battery Fitted) . Efficiency >65% (AC/DC & DC/DC) . Overtemperature,
Overvoltage & Overcurrent Protection (Latched Shutdown) . Fan Speed Control . Standard UPS
Contact Closure Compatible Interface . Logic On/Off . PS/2 (NLX) Style Case . ATX (NLX) 20-Way
Motherboard Connector
1. Output (standard)
| Nominal Voltage |
Min Load |
Max Load |
Regulation |
Ripple &
Noise |
| +5V DC |
0.3A |
20A (1) (3) |
+/-5% |
50mV |
| +3.3V DC |
0.5A |
20A (1) (3) |
+/-5% |
50mV |
| +12V1 DC |
1A |
8A (3) |
+/-5% (2) |
120mV |
| +12V2 DC |
1A |
14A |
+/-5% |
120mV |
| -12V DC |
0A |
0.5A |
+/-5% |
120mV |
| +5Vsb |
0A |
2.0A |
+/-5% |
50mV |
(1) The combined loading on the +5V DC and the +3.3V DC outputs must not exceed
130W.
(2) Total regulation +7%, -5% during battery operation
(3) Operation at higher load currents permissible subject to appropriate constraints
2. Overcurrent
| +5V, +3.3V, +12V |
Latched shutdown at <240VA (SELV Limit)
AC line or Logic On/Off recycle to restart. |
| -5V, -12V |
Short circuit protected. Latched shutdown.
AC line or Logic On/Off Recycle to restart. |
| +5Vsb |
Short Circuit protected. Automatic recovery |
3. Overvoltage
+5V, +3.3V, +12V, -
12V, -5V |
Latched shutdown at 5.6V to 7.0V, 3.76V to 4.8V, 13.0V to 15.6V respectively.
AC line or Logic On/Off Recycle to start. |
| +5Vsb |
Clamped at 5.9V to 6.5V. Automatic recovery |
4. Backup Battery
| Battery Type |
24V Lead acid |
| Charger Voltage |
27.6V (Temperature compensated) |
| Charger current limit |
0.8A (Max) |
| Other |
NiMH Available on request |
5. Approvals
| Safety |
NEMKO(EN60950); TUV EN60950 or VDE EN60950; CSAC22.2 no950-95; IEC60950; UL60950 |
| EMC |
EN55022: 1998+A1: 2000 Class B,
EN61000-3-2: 2000
EN61000-3-3: 1995+A1: 2001
CISPR 22: 1997+A1: 2000 Class B,
AS/NZS CISPR 22: 2002 Class B |
| Other |
CE Mark |
6. Control Interface
| PSON (LOGIC ON/OFF) |
BI-UPS® Input. TTL compatible siganl setting on/off state of unit.DC outputs enabled if pulled to logic low. DC outputs (excluding +5Vsb) disabled if driven to logic high or open circuited. |
| Power Good |
BI-UPS® Output. TTL compatible flag indicating status of +5V and +3.3V outputs. Set to logic high between 100ms and 500ms after both +5V and +3.3V outputs reach normal operating limits. Reset to logic low at least 1ms prior to either +5V or +3.3V outputs dropping out of normal operating limits. |
| Interface Enable |
BI-UPS® Input. Discrete signal to enable BI -UPS® control interface. Interface inactive if open circuited or held at logic low (-5 to -15V). Interface enabled if driven to logic high (+5 to +15V). |
| AC Fail |
BI-UPS® Output. RS232 compatible flag indicating failure of ac line voltage. ‘AC normal’ condition indicated by logic high (+5 to +15V); ‘AC fail’ by logic low (-5 to -15V) |
| Battery Backup Low |
BI-UPS® Output. RS232 compatible flag indicating battery backup voltage low. ‘Battery normal’ condition indicated by logic high (+5 to +15V); ‘Battery Low’ by logic low (-5 to -15V). |
| Shutdown |
BI-UPS® Input. Discrete signal enabled during battery back-up operation only. No action taken if held at logic low(<1V) or Open circuited. BI -UPS® shutdown initiated if driven to logic high (+5V to +15V). |
7. Environmental
| Storage Temperature |
-20 to +80° |
| Operating Temperature |
0 to 50°C |
| Humidity |
5 to 95% (non-condensing) |
| Maximum Altitude |
12,000ft (operating), 40,000ft (non-operating) |
| Vibration |
Sine wave excited. 0.25G max acceleration, 10-250Hz
(operating) |
| MTBF |
>100,000 hours calculated per MIL-HBK-217 (full-load, 25°C,
ground benign, ex fan) |
9. Cable Harness
| Designator |
PIN |
COLOUR |
FUNCTION |
Cable Length |
| P1 JP2416V2-20S And JP2416V2-4S |
1
2
3
4
5
6
7
8
9
10
11
12
13
13
14
15
16
17
18
19
20
21
22
23
24 |
Orange
Orange
Black
Red
Black
Red
Black
Grey
Purple
Yellow
Yellow
Orange
Orange
Brown
Blue
Black
Green
Black
Black
Black
Red
Red
Red
Black |
+3.3VDC
+3.3VDC
COM
+5VDC
COM
+5VDC
COM
Power On
+5Vsb
+12V1DC
+12V1DC
+3.3VDC
+3.3VDC
+3.3VDC Sense
-12VDC
COM
PSON
COM
COM
COM
-5VDC
+5VDC
+5VDC
COM |
500mm +20
/ -10
Pin8, 13sense,
14 + 16
24AWG
Pin9 20AWG
Remainder
18AWG |
P2
Molex CL1270H00 15P
or Equiv. |
1
2
3
4
5 |
Yellow
Black
Red
Black
Orange |
+12V1DC
COM
+5VDC
COM
+3.3V |
500mm +20
/ -10
20AWG |
P3
Molex 39-01-2040
Or Equiv. |
1
2
3
4 |
Black
Black
Yell/Black
Yell/Black |
COM
COM
+12V2
+12V2 |
500mm +20
/ -10
16AWG |
P4, P7
Amp 1-480424-0
Or Equiv. |
1
2
3
4 |
Yellow
Black
Black
Red |
+12V1
COM
COM
+5V |
400mm +20
/ -10
18AWG |
P5, P8
Amp 1-480424-0
Or Equiv. |
1
2
3
4 |
Yellow
Black
Black
Red |
+12V1
COM
COM
+5V |
150mm +10
/ -10
18AWG |
P6
Molex 171822-4
Or Equiv. |
1
2
3
4 |
Red
Black
Black
Yellow |
+5VDC
COM
COM
+12V1 |
150mm +10
/ -10
20AWG |
P13
Alex 6420-02M1 |
1
2 |
Red
Black |
Battery +VE
Battery –VE |
200mm
14AWG |
DB10A/DB10B
Molex 39-52-1105 |
1
2
3
4
5
6
7
8
9
10 |
Ribbon
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’ |
Battery Low
N/C
Negative Bias
Shutdown
Signal Ground
N/C
Interface enable
AC Fail
N/C
N/C |
440mm
28AWG |
10. Mechanical - Standard Chassis
|