Magnum's MPS1083 series

 


home > mps1083-000

MPS1083-000 57W UPS (BI-UPS®)

MPS1083
Magnum's MPS1083 series is an intelligent cost effective Power solution, tailored for the requirements of telephony Equipment manufacturers using Wireless Local Loop (WLL), Fibre to the Home (FTTH) and integrated access devices. The flexibility of this unit enables the OEM equipment Manufacturer to provide local power and protection for all their home and office telephony solutions.

Standard Features:

Output fully floating . Over-current protection . Over-voltage protection . Self contained convection cooling .AC Present LED indicator .Lead Acid battery charging . Battery Operation . Output signal .Battery OK output signal .Low Battery voltage disconnect .Compatible with 12Ah lead acid battery charging .High efficiency . Constant voltage charging with current limit .Wide ranging input

OPTIONAL FEATURES:
NiMH Charger . Custom output voltage . Custom interface . Custom PSU case and battery tray to suit customer requirements

1. General

Maximum continuous output power 57W
Maximum power on main output 50W continuous , 60W 10mS surge
Maximum to charge battery 7W
Input Voltage 87 to 265V ac (auto ranging)
Input Frequency 47 to 63Hz
Efficiency (full load) >65% in AC operation
>80% in battery operation
Over temperature protection Shutdown with auto-restart

2. Output (standard)

Output Voltage Max Load Peak Load (surge) Ripple & Noise
Main Output -51V
+2%,-8%
0.84A 1.2A 400mV
+12V DC 13.5V 0.52A None 7W

3. Charger (standard)

Battery Type +12V Lead Acid
Charger output voltage +13.5V (temperature compensated)

4. Overcurrent

-51V output Output folds back when overcurrent present overcurrent is 1.2A min to 1.6A max. Short circuit protection and meets SELV limits (240VA). Output recovers after fault condition has been removed.

5. Overvoltage

-51V output Latched shut down when output reaches –57V DC. Recycle power to restart unit.

6. Status Indicators

ACOK If AC power is present then the open collector output is pulled low. If AC power is present the green LED
illuminates
BOK If Battery power is present then the open
collector output is pulled low.

7. Approvals

Safety UL(UL1950), cUL(UL1950), NEMCO, CE
EMC (Emissions) EN55022 Class B
EMC (Immunity) EN61000-4-2, EN61000-4-4, EN61000-4-5

8. Environmental

Storage Temperature -40 to +65°
Operating Temperature -10 to 45°C
MTBF >130,000 hours calculated per MILHBK- 217F

9. Cable Harness

Designator Pin Function Description
J1
Schurter 4300.0097
L
N
Live
Neutral
Live connection
Neutral connection
J2 (DC output)
Wago 255-413
Note this connector is inside the chassis and is part of the power box
1
2
3
4
5
6
7
8
9
10
11
12
13
TIP1
RING1
TIP2
RING2
TX
RX
Shield
-BV
+BV
BOK
ACOK
-48RTN
-48VDC
Phone 1 TIP
Phone 1 RING
Phone 2 TIP
Phone 2 RING
Ibat Transmit
Ibat Receive
Earth
-ve battery
+ve battery
Battery status
ACpower status
-48V Return
-48V connection
J3
Amp 520250-2
1
2
TIP
RING
Phone 1 TIP
Phone 1 RING
J4
Amp 520250-2
1
2
TIP
RING
Phone 2 TIP
Phone 2 RING
IBAT
Samtec TSW-104-08-F-S-RA
1
2
3
GND
RX
TX
Ground
Ibat Transmit
Ibat Receive

10. Mechanical - Standard Chassis

 

More information



 
 

 
home | about us | contact us | gaming power supplies | battery back up | custom design power supplies
markets | touch screen technology | display monitors screens | technical glossary | FAQs
magnum news | related links | site map

European Head Office
4 Michaelson Square, Kirkton Campus, Livingston, Scotland, EH54 7DP
Tel: + 44 (0) 1506 463 330 | Fax: + 44 (0) 01506 463 320 | E-mail: sales@magnumpower.com
 

© Copyright 2005 Magnum Power Solutions Ltd and its licensors - All Rights Reserved