Magnum's MPS1058 series

 


home > mps1058-100

MPS1058-100 200Watt
(PS/2 Case, ATX-Style Connector,Contact-Closure-Compatible Control Interface.)

MPS1058-100 200 Watt

MPS1058-100 is a plug-in replacement for conventional AC input or DC input NLX/ATX form-factor switching power supplies. Primary input power may be derived from fixed utility supplies (85-264V AC 47 to 63Hz) or low voltage DC sources. In the event of a primary power failure, UPS action automatically cuts in to sustain all DC outputs. Suitable for operation in conjunction with Magnum 24V battery packs.

Features:

DC Input 11 to 30VDC *. Active PFC . Full UPS functionality . Wide-ranging AC Input (47Hz to 63Hz, 85V to 264V) . Six DC Outputs . Standby Output (+5Vsb/0.75A) . Hold-up Time >17ms (No Battery Fitted) . Efficiency >65% (AC/DC & DC/DC) . Overtemperature, Overvoltage & Overcurrent Protection (Latched Shutdown) . Fan Speed Control . Standard UPS Contact Closure Compatible Interface . Logic On/Off . PS/2 (NLX) Style Case . ATX (NLX) 20-Way Motherboard Connector

* Output power must be derated by 7W/V when running from a DC input less than 18V (e.g. Pout<158W at Vin=12VDC).

1. Output (standard)

Nominal Voltage Min Load Max Load Regulation Ripple &
Noise
+5V DC 1.5A 22A (1) (3) +/-5% 50mV
+3.3V DC 0A 12A (1) (3) +/-5% 50mV
+12V DC 0A 6A (3) +/-5% (2) 120mV
-5V DC 0A 0.5A +/-5% 100mV
-12V DC 0A 0.8A +/-5% 120mV
+5Vsb 0A 0.75A +/-5% 100mV

(1) The combined loading on the +5V DC and the +3.3V DC outputs must not exceed 120W.
(2) Total regulation +7%, -5% during battery operation.
(3) Operation at higher load currents permissible subject to appropriate constraints see section 2 for details.

2. Output (extended)

Nominal Voltage Min Load Max Load Regulation Ripple &
Noise
+5V DC 1.5A 25A (4) (6) +/-5% 50mV
+3.3V DC 0A 15A (4) +/-5% 50mV
+12V DC 0A 10A (5)

+/-5%
(7) (8)

120mV

(4) The combined loading on +5VDC and +3.3VDC must not exceed 120W.
(5) When drawing load current in excess of 6A on +12V a min load of +5V/3A or +3.3V/4.5A must be connected.
(6) When drawing in excess of 22A on +5V a minimum of +12V/1A must be connected.
(7) Regulation +7%,-5% when operating on battery and within constraints (5) and (6) above.
(8) Regulation +/- 7% when operating on line or battery and outwith constraints (5) and (6) above.

3. Overcurrent

+5V, +3.3V, +12V Latched shutdown at <240VA (SELV Limit)
AC line or Logic On/Off Recycle to restart.
-5V, -12V Short circuit protected. Latched shutdown.
AC line or Logic On/Off Recycle to restart.
+5Vsb Short Circuit protected. Automatic recovery

4. Overvoltage

+5V, +3.3V, +12V, -12V, -5V Latched shutdown at 5.6V to 6.6V, 3.7V to 4.5V, 13.2V to 15.6V, -15.6V to -13.2V, - 6.6V to -5.6V respectively.
AC line or Logic On/Off Recycle to start.
+5Vsb Clamped at 5.9V to 6.5V. Automatic recovery

5. Backup Battery

Battery Type 24V Lead acid
Charger Voltage 27.6V (Temperature compensated)
Charger current limit 0.8A (Max)

6. DC Input

Input Voltage Range 11V to 30V
Protection (reverse) User replaceable fuse
Efficiency DC to DC >65%
Input Connector 9-Way D-type, Pattern 7W2
Pin A = +DC, Pin B = Earth
Pin 1 = Earth, Pin 2 = Earth, Pin 3 = N/C,
Pin 4 = Reserved, Pin 5 = Reserved

7. Approvals

Safety UL(UL1950), cUL(UL1950), TUV(EN60950)
EMC (Emissions) EN55022 Class B, CISPR 22 Class B, FCC CFR 47 Part 15 Class B
EMC (Immunity) EN61000-4-2, EN61000-4-4, EN61000-4-5
EMC (Harmonic) EN61000-3-2
Other CE Mark

8. Control Interface

PSON (LOGIC ON/OFF) BI-UPS® Input. TTL compatible siganl setting on/off state of unit.DC outputs enabled if pulled to logic low. DC outputs (excluding +5Vsb) disabled if driven to logic high or open circuited.
Power Good BI-UPS® Output. TTL compatible flag indicating status of +5V and +3.3V outputs. Set to logic high between 100ms and 500ms after both +5V and +3.3V outputs reach normal operating limits. Reset to logic low at least 1ms prior to either +5V or +3.3V outputs dropping out of normal
operating limits.
Interface Enable BI-UPS® Input. Discrete signal to enable BI -UPS® control interface. Interface inactive if open circuited or held at logic low (-5 to -15V). Interface enabled if driven to logic high (+5 to +15V).
AC Fail BI-UPS® Output. RS232 compatible flag indicating failure of ac line voltage. ‘AC normal’ condition indicated by logic high (+5 to +15V); ‘AC fail’ by logic low (-5 to -15V)
Battery Backup Low BI-UPS® Output. RS232 compatible flag indicating battery backup voltage low. ‘Battery normal’ condition indicated by logic high (+5 to +15V); ‘Battery Low’ by logic low (-5 to -15V).
Shutdown BI-UPS® Input.Discrete signal enabled during battery back-up operation UPS® shutdown initiated if driven to logic high (+5V to +15V).

9. Environmental

Storage Temperature -40 to +85°
Operating Temperature 0 to 65°C (output power derated -5W/°C above 50°C)
Humidity 5 to 95% (non-condensing)
Maximum Altitude 12,000ft (operating), 40,000ft (non-operating)
Shock 15g pk for 11ms (operating), 30g pk for 11ms (non-operating)
Vibration 0.006 inch pk-pk @ 10 to 57Hz, 1.0g @ 57 to 150Hz (operating)
MTBF >80,000 hours calculated per MIL-HBK-217F (full-load, 35°C, ground benign, ex fan)

9. Cable Harness

Designator PIN COLOUR FUNCTION Cable Length
P1
Molex 39-01-2200

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Orange
Orange
Black
Red
Black
Red
Black
Grey
Violet
Yellow
Orange
Blue
Black
Green
Black
Black
Black
White
Red
Red
+3.3VDC
+3.3VDC
DC Return
+5VDC
DC Return
+5VDC
DC Return
Power Good
+5Vsb
+12VDC
+3.3VDC
-12VDC
DC Return
PSON
DC Return
DC Return
DC Return
-5VDC
+5VDC
+5VDC
300mm
18AWG
P2, 4
Molex 8981-04P
1
2
3
4
Yellow
Black
Black
Red
+12VDC
DC Return
DC Return
+5VDC
270mm
18AWG
P3, 5
Molex 8981-04P
1
2
3
4
Yellow
Black
Black
Red

+12VDC
DC Return
DC Return
+5VDC

425mm
18AWG
P6, 7
Amp 171822-4
1
2
3
4
Red
Black
Black
Yellow
+5VDC
DC Return
DC Return
+12VDC
805mm
22AWG
P11
Amp 171822-4
1
2
3
4
Red
Black
Black
Yellow
+5VDC
DC Return
DC Return
+12VDC
270mm
22AWG
P13
Alex 6420-02M1
1
2
Red
Black
Battery +VE
Battery –VE
200mm
14AWG
DB10A/DB10B
Molex 39-52-1105
1
2
3
4
5
6
7
8
9
10
Ribbon
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
Battery Low
N/C
Negative Bias
Shutdown
Signal Ground
N/C
Interface enable
AC Fail
N/C
N/C
440mm
28AWG

10. Mechanical - Standard Chassis

MPS1058-000

 

More information



 
 

 
home | about us | contact us | gaming power supplies | battery back up | custom design power supplies
markets | touch screen technology | display monitors screens | technical glossary | FAQs
magnum news | related links | site map

European Head Office
4 Michaelson Square, Kirkton Campus, Livingston, Scotland, EH54 7DP
Tel: + 44 (0) 1506 463 330 | Fax: + 44 (0) 01506 463 320 | E-mail: sales@magnumpower.com
 

© Copyright 2005 Magnum Power Solutions Ltd and its licensors - All Rights Reserved