Magnum's MPS1058 series

 


home > mps1058-000

MPS1058-000 200Watt UPS (BI-UPS®)
(PS/2 Case, ATX-Style Connector,Contact-Closure-Compatible Control Interface.)

MPS1058-00 200 Watt
MPS1058-000 is a plug-in replacement for conventional NLX/ATX form-factor switching power supplies. Units function as a normal power supply when AC line input is present and as truly on-line UPS during periods of power failure. Suitable for operation in conjunction with Magnum 24V battery packs.

Features:

200W Continuous DC Output Power . Active PFC . Full UPS functionality . Wide-ranging AC Input (47Hz to 63Hz, 85V to 264V) . Six DC Outputs . Standby Output (+5Vsb /0.75A) . Hold-up Time >17ms (No Battery Fitted) . Efficiency >65% (AC/DC & DC/DC) . Overtemperature, Overvoltage & Overcurrent Protection (Latched Shutdown) . Fan Speed Control . Standard UPS Contact Closure Compatible Interface . Logic On/Off . PS/2 (NLX) Style Case . ATX (NLX) 20-Way Motherboard Connector

1. Output (standard)

Nominal Voltage Min Load Max Load Regulation Ripple &
Noise
+5V DC 1.5A 22A (1) (3) +/-5% 50mV
+3.3V DC 0A 12A (1) (3) +/-5% 50mV
+12V DC 0A 6A (3) +/-5% (2) 120mV
-5V DC 0A 0.5A +/-5% 100mV
-12V DC 0A 0.8A +/-5% 120mV
+5Vsb 0A 0.75A +/-5% 100mV

(1) The combined loading on the +5V DC and the +3.3V DC outputs must not exceed 120W.
(2) Total regulation +7%, -5% during battery operation
(3) Operation at higher load currents permissible subject to appropriate constraints see section 2 for details.

2. Output (extended)

Nominal Voltage Min Load Max Load Regulation Ripple &
Noise
+5V DC 1.5A 25A (4) (6) +/-5% 50mV
+3.3V DC 0A 15A (4) +/-5% 50mV
+12V DC 0A 10A (5)

+/-5%
(7) (8)

120mV

(4) The combined loading on +5VDC and +3.3VDC must not exceed 120W.
(5) When drawing load current in excess of 6A on +12V a min load of +5V/3A or +3.3V/4.5A must be connected.
(6) When drawing in excess of 22A on +5V a minimum of +12V/1A must be connected.
(7) Regulation +7%,-5% when operating on battery and within constraints (5) and (6) above.
(8) Regulation +/- 7% when operating on line or battery and outwith constraints (5) and (6) above.

3. Overcurrent

+5V, +3.3V, +12V Latched shutdown at <240VA (SELV Limit)
AC line or Logic On/Off Recycle to restart.
-5V, -12V Short circuit protected. Latched shutdown.
AC line or Logic On/Off Recycle to restart.
+5Vsb Short Circuit protected. Automatic recovery

4. Overvoltage

+5V, +3.3V, +12V, -12V, -5V Latched shutdown at 5.6V to 6.6V, 3.7V to 4.5V, 13.2V to 15.6V, -15.6V to -13.2V, - 6.6V to -5.6V respectively.
AC line or Logic On/Off Recycle to start.
+5Vsb Clamped at 5.9V to 6.5V. Automatic recovery

5. Backup Battery

Battery Type 24V Lead acid
Charger Voltage 27.6V (Temperature compensated)
Charger current limit 0.8A (Max)
Available NiMH battery back-up on request

6. Approvals

Safety UL(UL1950), cUL(UL1950), TUV(EN60950)
EMC (Emissions) EN55022 Class B, CISPR 22 Class B, FCC CFR 47 Part 15 Class B
EMC (Immunity) EN61000-4-2, EN61000-4-4, EN61000-4-5
EMC (Harmonic) EN61000-3-2
Other CE Mark

7. Control Interface

PSON (LOGIC ON/OFF) BI-UPS® Input. TTL compatible siganl setting on/off state of unit.DC outputs enabled if pulled to logic low. DC outputs (excluding +5Vsb) disabled if driven to logic high or open circuited.
Power Good BI-UPS® Output. TTL compatible flag indicating status of +5V and +3.3V outputs. Set to logic high between 100ms and 500ms after both +5V and +3.3V outputs reach normal operating limits. Reset to logic low at least 1ms prior to either +5V or +3.3V outputs dropping out of normal
operating limits.
Interface Enable BI-UPS® Input. Discrete signal to enable BI -UPS® control interface. Interface inactive if open circuited or held at logic low (-5 to -15V). Interface enabled if driven to logic high (+5 to +15V).
AC Fail BI-UPS® Output. RS232 compatible flag indicating failure of ac line voltage. ‘AC normal’ condition indicated by logic high (+5 to +15V); ‘AC fail’ by logic low (-5 to -15V).
Battery Backup Low BI-UPS® Output. RS232 compatible flag indicating battery backup voltage low. ‘Battery normal’ condition indicated by logic high (+5 to +15V); ‘Battery Low’ by logic low (-5 to -15V).
Shutdown BI-UPS® Input.Discrete signal enabled during battery back-up operation only. No action taken if held at logic low(<1V) or Open circuited. BI-UPS® shutdown initiated if driven to logic high (+5V to +15V).

8. Environmental

Storage Temperature -40 to +85°
Operating Temperature 0 to 65°C (output power derated -5W/°C above 50°C)
Humidity 5 to 95% (non-condensing)
Maximum Altitude 12,000ft (operating), 40,000ft (non-operating)
Shock 15g pk for 11ms (operating), 30g pk for 11ms (non-operating)
Vibration 0.006 inch pk-pk @ 10 to 57Hz, 1.0g @ 57 to 150Hz (operating)
MTBF >80,000 hours calculated per MIL-HBK-217F (full-load, 35°C, ground benign, ex fan)

9. Cable Harness

Designator PIN COLOUR FUNCTION Cable Length
P1
Molex 39-01-2200

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Orange
Orange
Black
Red
Black
Red
Black
Grey
Violet
Yellow
Orange
Blue
Black
Green
Black
Black
Black
White
Red
Red
+3.3VDC
+3.3VDC
DC Return
+5VDC
DC Return
+5VDC
DC Return
Power Good
+5Vsb
+12VDC
+3.3VDC
-12VDC
DC Return
PSON
DC Return
DC Return
DC Return
-5VDC
+5VDC
+5VDC
300mm
18AWG
P2, 4
Molex 8981-04P
1
2
3
4
Yellow
Black
Black
Red
+12VDC
DC Return
DC Return
+5VDC
270mm
18AWG
P3, 5
Molex 8981-04P
1
2
3
4
Yellow
Black
Black
Red

+12VDC
DC Return
DC Return
+5VDC

425mm
18AWG
P6, 7
Amp 171822-4
1
2
3
4
Red
Black
Black
Yellow
+5VDC
DC Return
DC Return
+12VDC
805mm
22AWG
P11
Amp 171822-4
1
2
3
4
Red
Black
Black
Yellow
+5VDC
DC Return
DC Return
+12VDC
270mm
22AWG
P13
Alex 6420-02M1
1
2
Red
Black
Battery +VE
Battery –VE
200mm
14AWG
DB10A/DB10B
Molex 39-52-1105
1
2
3
4
5
6
7
8
9
10
Ribbon
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
Battery Low
N/C
Negative Bias
Shutdown
Signal Ground
N/C
Interface enable
AC Fail
N/C
N/C
440mm
28AWG

10. Mechanical - Standard Chassis

MPS1058-000

 

More information



 
 

 
home | about us | contact us | gaming power supplies | battery back up | custom design power supplies
markets | touch screen technology | display monitors screens | technical glossary | FAQs
magnum news | related links | site map

European Head Office
4 Michaelson Square, Kirkton Campus, Livingston, Scotland, EH54 7DP
Tel: + 44 (0) 1506 463 330 | Fax: + 44 (0) 01506 463 320 | E-mail: sales@magnumpower.com
 

© Copyright 2005 Magnum Power Solutions Ltd and its licensors - All Rights Reserved