MPS1058-000 200Watt
UPS (BI-UPS®)
(PS/2 Case, ATX-Style Connector,Contact-Closure-Compatible
Control Interface.)
MPS1058-000 is a plug-in replacement for conventional NLX/ATX form-factor
switching power supplies. Units function as a normal power supply
when AC line input is present and as truly on-line UPS during periods of
power failure. Suitable for operation in conjunction with Magnum 24V
battery packs.
Features:
200W Continuous DC Output Power . Active PFC . Full UPS functionality . Wide-ranging AC Input
(47Hz to 63Hz, 85V to 264V) . Six DC Outputs . Standby Output (+5Vsb /0.75A) . Hold-up Time >17ms (No
Battery Fitted) . Efficiency >65% (AC/DC & DC/DC) . Overtemperature, Overvoltage & Overcurrent Protection
(Latched Shutdown) . Fan Speed Control . Standard UPS Contact Closure Compatible Interface . Logic
On/Off . PS/2 (NLX) Style Case . ATX (NLX) 20-Way Motherboard Connector
1. Output (standard)
| Nominal Voltage |
Min Load |
Max Load |
Regulation |
Ripple &
Noise |
| +5V DC |
1.5A |
22A (1) (3) |
+/-5% |
50mV |
| +3.3V DC |
0A |
12A (1) (3) |
+/-5% |
50mV |
| +12V DC |
0A |
6A (3) |
+/-5% (2) |
120mV |
| -5V DC |
0A |
0.5A |
+/-5% |
100mV |
| -12V DC |
0A |
0.8A |
+/-5% |
120mV |
| +5Vsb |
0A |
0.75A |
+/-5% |
100mV |
(1) The combined loading on the +5V DC and the +3.3V DC outputs must not exceed
120W.
(2) Total regulation +7%, -5% during battery operation
(3) Operation at higher load currents permissible subject to appropriate constraints
see section 2 for details.
2. Output (extended)
| Nominal Voltage |
Min Load |
Max Load |
Regulation |
Ripple &
Noise |
| +5V DC |
1.5A |
25A (4) (6) |
+/-5% |
50mV |
| +3.3V DC |
0A |
15A (4) |
+/-5% |
50mV |
| +12V DC |
0A |
10A (5) |
+/-5%
(7) (8)
|
120mV |
(4) The combined loading on +5VDC and +3.3VDC must not exceed 120W.
(5) When drawing load current in excess of 6A on +12V a min load of +5V/3A or
+3.3V/4.5A must be connected.
(6) When drawing in excess of 22A on +5V a minimum of +12V/1A must be connected.
(7) Regulation +7%,-5% when operating on battery and within constraints (5) and (6) above.
(8) Regulation +/- 7% when operating on line or battery and outwith constraints (5) and (6)
above.
3. Overcurrent
| +5V, +3.3V, +12V |
Latched shutdown at <240VA (SELV Limit)
AC line or Logic On/Off Recycle to restart. |
| -5V, -12V |
Short circuit protected. Latched shutdown.
AC line or Logic On/Off Recycle to restart. |
| +5Vsb |
Short Circuit protected. Automatic recovery |
4. Overvoltage
| +5V, +3.3V, +12V, -12V, -5V |
Latched shutdown at 5.6V to 6.6V, 3.7V to 4.5V, 13.2V to 15.6V, -15.6V to -13.2V, - 6.6V to -5.6V respectively.
AC line or Logic On/Off Recycle to start. |
| +5Vsb |
Clamped at 5.9V to 6.5V. Automatic recovery |
5. Backup Battery
| Battery Type |
24V Lead acid |
| Charger Voltage |
27.6V (Temperature compensated) |
| Charger current limit |
0.8A (Max) |
| Available |
NiMH battery back-up on request |
6. Approvals
| Safety |
UL(UL1950), cUL(UL1950), TUV(EN60950) |
| EMC (Emissions) |
EN55022 Class B, CISPR 22 Class B, FCC CFR 47 Part 15 Class B |
| EMC (Immunity) |
EN61000-4-2, EN61000-4-4, EN61000-4-5 |
| EMC (Harmonic) |
EN61000-3-2 |
| Other |
CE Mark |
7. Control Interface
| PSON (LOGIC ON/OFF) |
BI-UPS® Input. TTL compatible siganl setting on/off state of unit.DC outputs enabled if pulled to logic low. DC outputs (excluding +5Vsb) disabled if driven to logic high or open circuited. |
| Power Good |
BI-UPS® Output. TTL compatible flag indicating status of +5V and +3.3V outputs. Set to logic high between 100ms and 500ms after both +5V and +3.3V outputs reach normal operating limits. Reset to logic low at least 1ms prior to either +5V or +3.3V outputs dropping out of normal
operating limits. |
| Interface Enable |
BI-UPS® Input. Discrete signal to enable BI -UPS® control interface. Interface inactive if open circuited or held at logic low (-5 to -15V). Interface enabled if driven to logic high (+5 to +15V). |
| AC Fail |
BI-UPS® Output. RS232 compatible flag indicating failure of ac line voltage. ‘AC normal’ condition indicated by logic high (+5 to +15V); ‘AC fail’ by logic low (-5 to -15V). |
| Battery Backup Low |
BI-UPS® Output. RS232 compatible flag indicating battery backup voltage low. ‘Battery normal’ condition indicated by logic high (+5 to +15V); ‘Battery Low’ by logic low (-5 to -15V). |
| Shutdown |
BI-UPS® Input.Discrete signal enabled during battery back-up operation only. No action taken if held at logic low(<1V) or Open circuited. BI-UPS® shutdown initiated if driven to logic high (+5V to +15V). |
8. Environmental
| Storage Temperature |
-40 to +85° |
| Operating Temperature |
0 to 65°C (output power derated -5W/°C above 50°C) |
| Humidity |
5 to 95% (non-condensing) |
| Maximum Altitude |
12,000ft (operating), 40,000ft (non-operating) |
| Shock |
15g pk for 11ms (operating), 30g pk for 11ms (non-operating) |
| Vibration |
0.006 inch pk-pk @ 10 to 57Hz, 1.0g @ 57 to 150Hz (operating) |
| MTBF |
>80,000 hours calculated per MIL-HBK-217F (full-load, 35°C, ground benign, ex fan) |
9. Cable Harness
| Designator |
PIN |
COLOUR |
FUNCTION |
Cable Length |
P1
Molex 39-01-2200 |
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
|
Orange
Orange
Black
Red
Black
Red
Black
Grey
Violet
Yellow
Orange
Blue
Black
Green
Black
Black
Black
White
Red
Red |
+3.3VDC
+3.3VDC
DC Return
+5VDC
DC Return
+5VDC
DC Return
Power Good
+5Vsb
+12VDC
+3.3VDC
-12VDC
DC Return
PSON
DC Return
DC Return
DC Return
-5VDC
+5VDC
+5VDC |
300mm
18AWG |
P2, 4
Molex 8981-04P |
1
2
3
4 |
Yellow
Black
Black
Red |
+12VDC
DC Return
DC Return
+5VDC |
270mm
18AWG |
P3, 5
Molex 8981-04P |
1
2
3
4 |
Yellow
Black
Black
Red |
+12VDC
DC Return
DC Return
+5VDC |
425mm
18AWG |
P6, 7
Amp 171822-4 |
1
2
3
4 |
Red
Black
Black
Yellow |
+5VDC
DC Return
DC Return
+12VDC |
805mm
22AWG |
P11
Amp 171822-4 |
1
2
3
4 |
Red
Black
Black
Yellow |
+5VDC
DC Return
DC Return
+12VDC |
270mm
22AWG |
P13
Alex 6420-02M1 |
1
2 |
Red
Black |
Battery +VE
Battery –VE |
200mm
14AWG |
DB10A/DB10B
Molex 39-52-1105 |
1
2
3
4
5
6
7
8
9
10 |
Ribbon
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’
‘’ |
Battery Low
N/C
Negative Bias
Shutdown
Signal Ground
N/C
Interface enable
AC Fail
N/C
N/C |
440mm
28AWG |
10. Mechanical - Standard Chassis
|